Measurement chip detects Legionella

Kategorie:
Autor: Jonas Völker

Measurement chip detects Legionella

Legionella are rod-shaped bacteria that can cause life-threatening pneumonia in humans. They multiply in warm water and can be dispersed into the air via cooling towers, evaporative recooling systems and hot water systems.
The most dangerous among the almost 50 species of Legionella is Legionella pneumophila. It is responsible for 80 percent of all infections. When an outbreak occurs, the source of the germs must be identified as soon as possible to prevent further infections.
Similar to a paternity test, the origin of the outbreak is confirmed when the germs in the process water of a technical system exactly match those identified in the patient. However, often numerous systems must be tested in the process, and the requisite cultivation for the test takes around ten days.

FASTER DETECTION WITH ANTIBODIES

Meanwhile there is a rapid test for detecting the Legionella pathogen in the clinic. It identifies compounds of Legionella in the urine of patients. "Unfortunately, this quick test serves only as a first indication and is not suitable for screening the water of technical systems," says PD Dr. Michael Seidel, head of the research group at the Chair of Analytical Chemistry and Water Chemistry of the Technical University of Munich.
The team of scientists thus developed a measuring chip in the context of the "LegioTyper" project funded by the German Federal Ministry of Education and Research. This chip not only detects the dangerous pathogen Legionella pneumophila but also identifies which of the approximately 20 subtypes is present.

FAST, INEXPENSIVE AND VERSATILE

The foil-based measuring chip uses the microarray analysis platform MCR of the Munich company GWK GmbH. Using 20 different antibodies, the system provides a complete analysis within 34 minutes.
"Compared to previous measurements, the new method not only provides a huge speed advantage," says Michael Seidel, "but is also so cheap that we can use the chip in one-time applications."
The system can be deployed for environmental hygiene as well as clinical diagnostics. In combination with a second, DNA-based method, the system can even distinguish between dead and living Legionella pathogens. This allows the success of disinfection measures to be monitored. The project participants will present their system to the public for the first time at the Analytica 2018 trade fair in Munich (Hall 3, Booth 315; April 10–13, 2018).

PUBLICATION:

Wunderlich, A.; Torggler, C.; Elsaesser, D.; Lück, C.; Niessner, R.; Seidel, M., Rapid quantification method for Legionella pneumophila in surface water. Analytical and Bioanalytical Chemistry 2016, 408(9), 2203-2213 – DOI: 10.1007/s00216-016-9362-x.
Kober, C.; Niessner, R.; Seidel, M. Quantification of viable and non-viable Legionella spp. by heterogeneous asymmetric recombinase polymerase amplification (haRPA) on a flow-based chemiluminescence microarray. Biosensors and Bioelectronics, 2018, 100, 49-55. doi.org/10.1016/j.bios.2017.08.053

MORE INFORMATION:

The LegioTyper project is funded by the German Federal Ministry of Education and Research in the context of the "Civil Security – Protection against biological threats and pandemics" program. The antibodies were provided by the German Reference Laboratory for Legionella at the TU Dresden.

Source/Further information: www.tum.de

Das könnte Sie auch interessieren:

Online-Seminar zur Generalentwässerungsplanung
VKU erweitert Vorstand und nimmt Mitglieder auf
Honorary Fellowship Award goes to Harry Seah

Passende Firmen zum Thema:

WEHRLE Umwelt GmbH

Themen: Industriewasser | Wasseraufbereitung | Abwasserbehandlung

Mit den drei Geschäftsbereichen Energietechnik, Umwelttechnik, Fertigung und mehreren internationalen Tochtergesellschaften und Partnern entwickelt, plant, liefert und betreibt WEHRLE Anlagen und Komponenten zur Energieerzeugung aus Verbrennungsprozessen, Klärschlammverbrennung zur

Publikationen

Fused connecting lines made of HDPE in Düsseldorf

Fused connecting lines made of HDPE in Düsseldorf

Autor: Alexander Schuir / Hanjo Kanne / Kai Büßecker
Themenbereich: 3R

Home to about 600,000 inhabitants, the state capital of North Rhine-Westphalia Düsseldorf, like any other city, is constantly endeavouring to provide its citizens, commuters, and guests with a fully functional infrastructure to meet the demands of ...

Zum Produkt

Quality Assurance and modern data management

Quality Assurance and modern data management

Autor: Jörg Sebastian
Themenbereich: 3R

...

Zum Produkt

Rehabilitation of large profiles lacking long-term stability

Rehabilitation of large profiles lacking long-term stability

Autor: Dietmar Beckmann / Heinz Doll / Vladimir Lacmanović
Themenbereich: 3R

Many large interceptor sewers, predominantly installed under public roads, have been in use for over 100 years. They are made of brickwork or compressed concrete and often show serious damage, so that it would seem that long-term stability can no ...

Zum Produkt

Mehr Publikationen...